-40%

DC 4-12V Mini Wireless Remote Control System with 5A Relay Output

$ 17.42

Availability: 100 in stock
  • Brand: CaryMart
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Return shipping will be paid by: Buyer
  • Condition: New
  • Type: Remote Control
  • Item must be returned within: 30 Days
  • MPN: Does Not Apply
  • All returns accepted: Returns Accepted

    Description

    0020647
    DC  4-12V Mini Wireless Remote Control System with 5A Relay Output
    Model:  0020647
    Package Include:
    1 x Receiver: S1UC-DC(4~12V)
    1 x Transmitter: C-2
    1 x User manual
    Feature:
    Wireless control, easy to install.
    Super mini size.
    5A relay output.
    Control lights, motors, electric doors or locks, or other appliances with  voltage AC110~240V or DC0~28V.
    You can turn on/off the receiver with transmitter (remote control) from any  place within a reliable distance; the wireless RF signal can pass through walls,  floors and doors.
    With characteristics of reverse power protection.
    Reliable control: The receiver can be only triggered by the transmitters which  have learned.
    One/ several transmitters can control one/ several receivers simultaneously.
    Transmitting Frequency: 315MHz / 433MHz
    Receiver:
    Model No.: S1UC-DC(4~12V)
    Channel: 1 CH
    Control Modes: Momentary, Self-Locking, Interlocking
    Coding Type: Fixed code or Learning code
    Coding Setting: By learning
    Power Supply (Operating Voltage): DC 4~12V
    Output: Relay output (Normally open and normally closed)
    Working Voltage Range of Relay: AC110~240V or DC0~28V
    PCB Size: 34mm x 23mm x 17mm
    Static Current: ≤7mA
    Maximum Working Current of Relay: 5A
    Receiver Working Current: 30mA
    Transmitter:
    Model No.: 0021001 (C-2)
    With Sliding Cover: Slide up when it doesn’t work (to protect the button). Slide  down the button will appear.
    Shell Color: Wood Color / White/ Black
    Channel/Button: 2
    Button Symbol:1, 2
    Operating Voltage: 12V (1 x 23A -12V battery, can be used for 12 months)
    Operating Current: 6mA
    Operating Frequency: 315Mhz / 433Mhz
    Encoding Chip: PT2262/ PT2264/ SC2262
    Encoding Type: Fixed code by soldering, up to 6561 codes.
    Transmitting Distance: 100m / 300ft (theoretically)
    The distance of 100m is a theoretical data, it shall be operated in an open  ground, no barriers, no any interference. But in the practice, it will be  hindered by trees, walls or other constructions,
    and will be exposed to some interference by other signals. Therefore, the actual  distance may or may not reach 100m.
    If you stretches the telescopic antenna, it can have a further working range,  which is twice as much as it used to be.
    Modulation Mode: ASK
    Operating Temperature: -20 ° C to +70 ° C
    Unit Size: 58mm x 39mm x 16mm
    Weight: 30g
    Uses: garage doors, motorcycles, car alarm products, home security products,  wireless remote control products, industrial control products.
    Matching Transmitters:
    The receiver can work with different transmitters, such as model C-1 / C-2  (100M), CWB-1 / CWB-2 (50M, waterproof), CP-1 / CP-2 (500M), or CB-1 / CB-2  (1000M) etc.
    When you set the receiver in Self-Locking or Momentary mode, it should work with  single button transmitter, such as model C-1 (100M), CWB-1 (50M, waterproof),  CP-1 (500M), or CB-1 (1000M) etc. When you set the receiver in Interlocking  mode, it should work with two buttons transmitter, such as model C-2 (100M),  CWB-2 (50M, waterproof), CP-2 (500M), or CB-2 (1000M) etc.
    Working Range:
    With a transmitter (such as C-2) to form a complete set, the maximum working  distance can reach 100M in an open ground.
    The maximum working distance is a theoretical data, it shall be operated in an  open ground, no barriers, no any interference. But in the practice, it will be  hindered by trees, walls or other constructions, and will be interfered by other  wireless signals. Therefore, the actual distance may not reach this maximum  working distance.
    Usage (with the  transmitter C-2):
    The receiver can be used to control both DC 0~28V and AC 110~240V  equipments.
    Notice: The receiver is relay output, not DC/AC power output. Initial state of  relay output terminals: Terminals NO and COM are Normally Open; Terminals NC and  COM are Normally Closed.
    1. Wiring:
    If you want to control a DC 12V lamp, do as following:
    1) Connect the positive pole of DC power supply to terminal “V+”, and connect  the negative pole of DC power supply to terminal “V-”.
    2) Connect terminal NO to the positive pole of DC power supply, connect terminal  COM to the positive pole of DC lamp, and connect the negative pole of DC lamp to  the negative pole of DC power supply.
    If you want to control an AC 220V lamp, do as following:
    1) Connect the positive pole of DC power supply to terminal “V+”, and connect  the negative pole of DC power supply to terminal “V-”.
    2) Connect terminal NO to the live wire of AC power supply, connect terminal COM  to one side of AC lamp, and connect another side of AC lamp to the neutral wire  of AC power supply.
    2. Setting different control modes:
    We have set the receiver as interlocking control mode before delivery. If  you want to use other control modes, do as following operation:
    Setting Interlocking mode: Connect a pins between terminals L and G.
    Interlocking mode: Press button 1 -> On; Press button 2 -> Off.
    Press button 1: The relay is activated (connect terminals NO and COM, disconnect  terminals NC and COM), and the connected lamp is turned on.
    Press button 2: The relay is deactivated (connect terminals NC and COM,  disconnect terminals NO and COM), and the connected lamp is turned off.
    Setting Self-Locking mode: Do not connect the pin.
    Self-Locking mode: Press button -> On; Press button again -> Off.
    Press button 1: The relay is activated (connect terminals NO and COM, disconnect  terminals NC and COM), and the connected lamp is turned on.
    Press button 1 again: The relay is deactivated (connect terminals NC and COM,  disconnect terminals NO and COM), and the connected lamp is turned off.
    Setting Momentary mode: Connect a pins between terminals M and G.
    Momentary mode: Press and hold button -> On; Release button -> Off.
    Press and hold button 1: The relay is activated (connect terminals NO and COM,  disconnect terminals NC and COM), and the connected lamp is turned on.
    Release button 1: The relay is deactivated (connect terminals NC and COM,  disconnect terminals NO and COM), and the connected lamp is turned off.
    How to pair the transmitter to the receiver:
    1) Press the learning button of receiver, signal LED on the receiver flashes  slowly, and the receiver enters into status of LEARNING.
    2) If you set the receiver in interlocking mode, you need to operate the  receiver to learn two buttons of transmitter. The operations as follows:
    Press button 1 on transmitter, if signal LED flashes quickly twice then flashes  slowly, it means learning of button 1 is successful. Then press button 2 on  transmitter, if signal LED flashes quickly twice then off, it means learning of  button 2 is successful. The receiver exits the learning process.
    3) If you set the receiver in momentary mode or self-Locking mode, you need to  operate the receiver to learn one button of transmitter. The operations as  follows:
    Press button 1 on transmitter, if signal LED flashes quickly twice then flashes  slowly, it means learning of button 1 is successful. At this time, you can press  the learning button of receiver to exit the learning process and signal LED  turned off.
    4) The receiver can learn up to 6 buttons with different codes.
    Delete all transmitters:
    We have learned transmitter to the receiver. If you don’t want the receiver  to work with the transmitter, you can delete all codes of transmitter, which are  stored in the receiver.
    Operation: Press and hold the learning button of receiver until signal LED  turned on then off; release the learning button. That means all stored codes  have been deleted successfully.