-40%

DC Current Trigger Transmitter And AC 110V 220V Power Output Receiver

$ 45.93

Availability: 100 in stock
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 30 Days
  • Type: Remote Control
  • Brand: CaryMart
  • Refund will be given as: Money back or replacement (buyer's choice)
  • MPN: Does Not Apply
  • Condition: New

    Description

    0020523
    DC Current Trigger Transmitter And AC 110V 220V Power Output Receiver
    Model: 0020523
    Package Include:
    1 x Receiver: S1X-AC-ANT3
    1 x Transmitter: CB-2V
    1 x User manual
    Feature:
    Application: It can be used in industry automation, agriculture automation and home automation, such as factory, house, farm, pasture, vehicle, ship, offshore operation, aerial vehicle, field call, etc. It can remote control equipments on land, water and air, such as remote control lights, sirens, locks, motors, fans, winches, blinds, linear actuators, doors, windows, electric solenoid valves, security alarm, business signs and various devices.
    Wireless control, easy to install.
    Waterproof: The receiver has waterproof case and waterproof connector, it can be installed outdoors.
    Universal input: Support voltage of AC110V (100V~120V), widely used in US, Canada... and voltage of AC220V (200V~240V), used in UK, France...
    AC Power Output: It can control AC equipment with voltage 110V / 120V / 220V / 240V AC.
    With wired control terminals: You can connect sensors, limit switches, manual switches or external devices to control the receiver.
    With the external antenna, it can have a further working range.
    You can turn on/ off the receiver with transmitter (remote control) from any place within a reliable distance.
    Wireless RF signal can pass through walls, floors, doors or windows.
    With reverse power protection and over current protection.
    Reliable control: The receiver only works with the transmitter which use same code.
    One/several transmitters can control one/several receivers simultaneously.
    You can use two or more units in the same place.
    Receiver Parameters:
    Model No.: S1X-AC-ANT3
    Power Supply (Operating Voltage): AC100~240V (110V/120V/220V/240V)
    Output: AC100~240V (110V/120V/220V/240V)
    Working Frequency: 315MHz
    Channel: 1 CH
    Control Modes: Latched
    Static Current: ≤6mA
    Maximum Working Current: 10A
    PCB size: 90mm x 59mm x 18mm
    Case size: 100mm x 68mm x 50mm
    Work with Fixed code transmitters or Learning code transmitters.
    Terminal Parameters of receiver:
    Wire range:≤12 AWG
    Temperature range: -40℃ ~ +105℃
    Screw:M3
    External Telescopic Antenna (ANT3) for the receiver:
    Length of external telescopic antenna: 108mm / 445mm (stretch)
    With SMA connector.
    If you stretches the external telescopic antenna, it can have a further working range.
    Transmitter Parameters:
    Model No.: CB-2V
    With DC Power Trigger Input Wires
    Trigger Input: DC5~28V
    Channel/Button: 2
    Operating Voltage: 9V (1 x 6F22 -9V battery, can be used for a week, if you want a longer working time, please use a 9V power adapter.)
    Operating Current: 30mA
    Operating Frequency: 315 MHz
    Transmitting Distance: 1000m / 3000ft (theoretically)
    It has an on / off button on the side.
    Modulation Mode: ASK
    Operating Temperature: -20 ° C to +70 ° C
    Unit Size: 135mm x 42mm x 25mm
    Working Range:
    Super long range, with a transmitter (such as CB-2V) to form a complete set, the maximum working distance can reach 2000Min an open ground.
    The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will be hindered by trees, walls or other constructions, and will be interfered by other wireless signals. Therefore, the actual distance may not reach this maximum working distance.
    Usage:
    The receiver can be used to control AC 110~240V equipments.
    A. Wiring:
    If you want to control an AC 220V lamp, do as following:
    1) Connect the live wire of AC power supply to terminal “L / +” of INPUT, and connect the neutral wire of AC power supply to terminal “N / -” of INPUT.
    2) Connect one side of AC lamp to terminal "L / +" of OUTPUT, and connect another side of AC lamp to terminal "N / -" of OUTPUT.
    B. Operation:
    1) Controlling the device by pressing buttons on the transmitter (CB-2V):
    Press button A of the transmitter: Terminals “OUT1”of the receiver outputs DC power, the lamp is turned on.
    Press button B of the transmitter: Terminals “OUT1” of the receiver stops outputting, the lamp is turned off.
    2) Controlling the device by inputting DC5~28V power to the input wire of the transmitter:
    When connect DC5~28V power to the input wire (the red wire and black wire) of the transmitter, the transmitter sends an RF signal "ON" to trigger the receiver, the output terminals "OUT1" outputs DC power, and the lamp is turned on.
    When disconnect DC5~28V power to the input wire, the transmitter sends another RF signal "OFF" to trigger the receiver, the output terminals "OUT1" stops outputting, and the lamp is turned off.
    C. Wired control terminals:
    The receiver has wired control terminals, you can connect external devices, sensors, limit switches or manual switches to trigger the receiver.
    1) By low level signal:
    You can connect external devices (with low level output signal) to trigger the receiver.
    When external device outputs low level signal to terminals 1 (Signal +) and terminal 3 (Signal -), terminal of OUT 1 output AC power, and the lamp is turned on.
    When external device stops to output signal, terminal of OUT 1 stop outputting, and the lamp is turned off.
    2) By NO/NC contact:
    You can connect manual switches (with NO/NC contact) to trigger the receiver.
    When connect terminals 1 and 3 by manual switch, terminal of OUT 1 output AC power, and the lamp is turned on.
    When disconnect terminals 1 and 3 by manual switch, terminal of OUT 1 stop outputting, and the lamp is turned off.